ABIBLOG English

Weekly Maintenance on a TMS-VI Front Injector for Cleaning Stations

Written by Danny Seddon | Aug 20, 2018 12:45:25 PM

The front injector TMS-VI is nearly service-free.

However, it is important to carry out regular cleaning and inspection of the mechanical parts to make sure the equipment is fully functional and has a long life cycle. For correct setup procedure, see the manual provided with each unit.

 PLEASE NOTE: 

Before carrying out cleaning, servicing & repair work the following shut down procedure must be followed.

  • Switch off the robot control.
  • Shut-off the compressed air supply.
Make sure that this remains the case throughout the entire time you are servicing the machine.

 

Step  1 

  • Using compressed air blow off any debris which has settled on and around the front injector. Eye protection should be worn.

 

 

 

 

 

 

Step  2 

  • Disconnect the air supply (A) to the venturi valve along with the fluid hose  to the adjuster (B)
  • Blow compressed air into air supply (A) to remove any debris from the injector.
  • NOTE: Ensure that the air supply is      re-connected to A & the fluid hose is    re-connected to B.

 

 

 

 

Step  3 


  • Check the collection tray and if necessary remove any blockage from the drain hole.


 

 

 

 

 

 

Step  4 

  • Check the level of anti-spatter. Depending on the number of shifts / welding hours this may need to be   done daily.
  • We recommend only BINZEL anti-spatter fluid is used.

 

 Waste anti-spatter fluid should never be        re-used as this could cause system blockages 

 

 

 

 

Thank you once again for reading our blog, if you found it helpful you may also be interesting in reading TMS-VI Troubleshooting Guide for Your Torch Cleaning Station